Auto memories, User presets commands, Presets commands – Extron Electronics DSC HD-3G A User Guide User Manual
Page 59
Command
ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Presets
Auto Memories
Enable
E
1 * 1 AMEM
}
Amem 1 * 1
]
Set Auto Memory to On.
Settings are automatically
stored as presets. Previous
settings for the incoming signal
are recalled.
Disable
E
1 * 0 AMEM
}
Amem 1 * 0
]
Set Auto Memory to Off.
Manual recall of input presets is
required to configure the input.
View setting
E
1 AMEM
}
X1)
]
In verbose modes 2 and 3:
Amem 1 *
X1)
]
View current Auto Memory
status
X1)
.
Values Saved in User and Input Presets:
User Presets
Input Presets
Contrast
H Image Size
Contrast
H Start
H Image Position
Brightness
V Image Size
Brightness
V Start
V Image Position
Detail
H Image Position
Detail
H Active (Pixels)
H Image Size
Preset Name
V Image Position
Film Mode
V Active (Lines)
V Image Size
Audio Gain/Attenuation
Total Pixels
Preset Name
User Presets
Recall preset
1 *
X2%
.
1 Rpr
X2%
]
Recall user preset
X2%
for the
selected input.
Save preset
1 *
X2%
,
1 Spr
X2%
]
Save user preset
X2%
for the
selected input.
Delete (clear) preset
E
X 1 *
X2%
PRST
}
Prst X 1*
X2%
]
Clear user preset
X2%
and set
its name to [unassigned].
User Preset Name
Write name
E
1 *
X2%
,
X1$
PNAM
}
Pnam 1*
X2%
,
X1$
]
Set the name of user preset
X2%
to
X1$
.
Read name
E
1 *
X2%
PNAM
}
X1$
]
In verbose modes 2 and 3:
Pnam 1 *
X2%
,
X1$
]
View the name of user preset
X2%
.
NOTE:
Unnamed presets are shown as [unassigned]. To restore a default user preset name, enter a single space
character for
X1$
. These entries are valid only for previously saved presets.
NOTE:
X1)
= Enable or disable Auto Memory: 0 = Off or disable, 1 = On or enable
X1$
= Preset name, up to 16 characters
X2%
= User preset number: 1 – 3
Response is 2 digits padded with a zero.
DSC 3G-HD A and DSC HD-3G A • Remote Configuration and Control
53