Asus GigaX2048 User Manual
Page 106
94
GigaX2024/2048 L2 Managed Switch User Manual
Problem
Suggested Action
PCs cannot display web
configuration pages.
1.The switch is powered up and the
connecting port is enabled. The factory
default IP for the switch is 192.168.1.1.
2.Verify your network setup in your PC for this information.
If your PC does not have a valid route to access the
switch, change the switch IP to an appropriate IP that your
PC can access.
3.Ping “switch IP” from the PC, if it still fails, repeat step 2.
4.If ping is successful but the web configuration still fails,
connecting PC through the console port by a RS232 or
USB, check if any filter rule or static MAC address is set to
block the WEB traffics.
Web Configuration Interface
You forgot/lost your WEB
Configuration Interface
user ID or password.
1.If you have not changed the password from the default,
try using “admin” as the user ID and bypassing password.
2.Login to console mode through RS232 or USB,
use “sys user show” to display the lost information
Some pages do not
display completely
1.Verify that you are using Internet Explorer v5.5
or later. Netscape is not supported. Support for
Javascript
®
must be enabled in your browser.
Support for Java
®
may also be required.
2.Ping the switch IP address to see if the link
is stable. If some ping packets fail, check your
network setup to make sure a valid setting.
Changes to Configuration
are not being retained.
Be sure to click on
Save button in the Save
Configuration page to save any changes.
Console Interface
Cannot show the texts
on the terminal emulator.
1.The factory default baud rate is 9600, no flow control,
8 bit data, no parity check and stop bit is one.
2.Change your terminal emulator setup to
this number. If you are using USB to connect
the switch, install the USB driver first.
3.Check if the cable is good.