2 × 12a digital dual microdlynx, Non-isolated dc-dc power modules, Datasheet – GE Industrial Solutions 2 × 12A Digital Dual Output MicroDLynx User Manual
Page 26

GE
Datasheet
2 × 12A Digital Dual MicroDlynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc –14.4Vdc input; 0.51Vdc to 5.5Vdc output; 2 × 12AOutput Current
February 14, 2014
©2014 General Electric Corporation. All rights reserved.
Page 26
Hex
Code
Command
Brief Description
Non-Volatile
Memory Storage
4F
OT_FAULT_LIMIT
Value may be locked
Sets the overtemperature fault level in °C
Format
Linear, two’s complement binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r
Function
Exponent Mantissa
Default Value
0 0 0 0 0 0 0 0
Bit Position
7 6 5 4 3 2 1 0
Access
r/w r/w r/w
r/w
r/w
r/w
r/w r/w
Function
Mantissa
Default Value
1 0 0 0 0 1 1 1
YES
51
OT_WARN_LIMIT
Value may be locked
Sets the over temperature warning level in °C
Format
Linear, two’s complement binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r
Function
Exponent Mantissa
Default Value
0 0 0 0 0 0 0 0
Bit Position
7 6 5 4 3 2 1 0
Access
r/w r/w r/w
r/w
r/w
r/w
r/w r/w
Function
Mantissa
Default Value
0 1 1 1 1 1 0 1
YES
61 TON_RISE
Sets the rise time of the output voltage during startup.
Supported Values – 0.6, 0.9, 1.2, 1.8, 2.7, 4.2, 6.0, 9.0msec. Value of 0 instructs unit to
bring its output to programmed value as quickly as possible
Format
Linear, two’s complement binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r/w
Function
Exponent Mantissa
Default Value
1 1 1 0 0 0 0 0
Bit Position
7 6 5 4 3 2 1 0
Access
r/w r/w r/w
r/w
r/w
r/w
r/w r/w
Function
Mantissa
Default Value
0 0 1 0 1 0 1 1
YES
78 STATUS_BYTE
Returns one byte of information with a summary of the most critical module faults
Format
Unsigned Binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r
Flag
X OFF
VOUT
_OV
IOUT_
OC
VIN_U
V
TEMP CML
None
of the
Above
Default Value
0 0 0 0 0 0 0 0
79 STATUS_WORD
Returns two bytes of information with a summary of the module’s fault/warning
conditions
Format
Unsigned Binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r
Flag
VOUT IOUT/P
OUT
X MFR
PGOOD
X X X
Default Value
0 0 0 0 0 0 0 0
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r
Flag
X OFF VOUT_
OV
IOUT_
OC
VIN_U
V
TEMP CML
None
of the
above
Default Value
0 X 0 0 0 0 0 0
7A STATUS_VOUT
Returns one byte of information with the status of the module’s output voltage related
faults
Format
Unsigned Binary
Bit Position
7 6
5 4 3
2
1
0
Access
r r
r
r
r
r
r r
Flag
VOUT_OV X X VOUT_UV X X X X
Default Value
0 0
0 0 0
0
0
0