Q: What is the maximum scan-rate in the RS-485 network?

A:

The scan-rate depends on the baud rate of the RS-232 COM port,

checksum status, module numbers, channels, commands to send, result
string received and system performance.

To test, use those conditions:

I-7012 module: x 1
Channel: x 1
Baud Rate: 115200 bps
Command: #AA (cr)(null) ==> 5 Chars
Result: >SDDDDDD (cr) ==> 9 Chars

1 Char: 1 Start bit + 8 Data bits + 1 Stop bit = 10 bits
Every communication: Command string + Result string
= 14 Chars = 140 bits
140 (bits/communication) / 115200 (bits/sec)
= 0.00122 (sec/communication)
Hardware delay (every communication): 1 mSec
Scan rate: 1/ (0.00122 + 0.001) = 450 (communication/sec)

Estimated scan rate:

450 times/sec maximum.

Tested value of scan rate:

440 times/sec maximum without system message processing.
360 times/sec maximum with system message processing.

Note: System message processing lets the OS process other tasks. This may
reduce the program performance.