Special Instructions for Installation and Operation

in a Class 1 Div 2 Environment


When this device is operated in a Class 1 Div 2 environment, the following PRECAUTIONS and WARNINGS must be observed:

1. Power, input and output (I/O) wiring must be in accordance with Class 1 Division 2 wiring methods [Article 501.10(B) of the

National Electrical Code, NFPA 70] and in accordance with the authority having jurisdiction.

2. WARNING – EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS 1,

DIVISION 2.

3. WARNING – EXPLOSION HAZARD – WHEN IN HAZARDOUS LOCATIONS, TURN OFF POWER BEFORE REPLACING OR

WIRING MODULES.

4. WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF

OR THE AREA IS KNOWN TO BE NON-HAZARDOUS.

5. WARNING – THIS APPARATUS IS SUITABLE FOR USE IN CLASS 1, DIVISION 2, GROUPS A, B, C, AND D, OR

UNCLASSIFIED LOCATIONS.