Table 72, Table 73, Min for a logic “1” and v – Rainbow Electronics T89C5115 User Manual
Page 96: Max for a logic “0
96
T89C5115
4128A–8051–04/02
Table 72. AC Parameters for a Variable Clock
Shift Register Timing Waveforms
External Clock Drive
Characteristics (XTAL1)
Table 73. AC Parameters
External Clock Drive
Waveforms
AC Testing Input/Output
Waveforms
AC inputs during testing are driven at V
CC
- 0.5 for a logic “1” and 0.45V for a logic “0”.
Timing measurement are made at V
IH
min for a logic “1” and V
IL
max for a logic “0”.
Symbol
Type
Standard
Clock
X2 Clock
X parameter
for -M range
Units
T
XLXL
Min
12 T
6 T
ns
T
QVHX
Min
10 T - x
5 T - x
50
ns
T
XHQX
Min
2 T - x
T - x
20
ns
T
XHDX
Min
x
x
0
ns
T
XHDV
Max
10 T - x
5 T- x
133
ns
VALID
VALID
VALID
VALID
VALID
VALID
INPUT DATA
VALID
0
1
2
3
4
5
6
8
7
ALE
CLOCK
OUTPUT DATA
WRITE to SBUF
CLEAR RI
T
XLXL
T
QVXH
T
XHQX
T
XHDV
T
XHDX
SET TI
SET RI
INSTRUCTION
0
1
2
3
4
5
6
7
VALID
Symbol
Parameter
Min
Max
Units
T
CLCL
Oscillator Period
25
ns
T
CHCX
High Time
5
ns
T
CLCX
Low Time
5
ns
T
CLCH
Rise Time
5
ns
T
CHCL
Fall Time
5
ns
T
CHCX
/T
CLCX
Cyclic ratio in X2 mode
40
60
%
V
CC
-0.5V
0.45V
0.7V
CC
0.2V
CC
-0.1
T
CHCL
T
CLCX
T
CLCL
T
CLCH
T
CHCX
INPUT/OUTPUT
0.2 V
CC
+ 0.9
0.2 V
CC
- 0.1
V
CC
-0.5V
0.45 V