beautypg.com

Page head smpte, File, Options – TC Electronic Broadcast 6000 User Manual

Page 46: Current list, Remote device disk drive, Automation timecode options

background image

46

paGe Head

smpTe

Step/Adjust
Range: Frame, 1 Second, 10 Seconds, 1 min.,

10 min. or 1 hour.

Use the Step parameter to select Adjust range and the

Adjust parameter to increase/decrease the time.

Device
This parameter selects which Mainframe connected to the

LAN you are working on. Device numbers 1-8, corresponds

to the Device position at the Select page.

Preset Type
Selects whether the preset Event you are working on is a

Scene, Routing, Engine or a System preset.

Bank
Select the bank related to the preset you are about to

setup/recall via SMPTE.

Preset
Select the preset from the selected bank

File

Current List

Keep
Press to save the Event List locally on the Icon. It is possible

to save one Event List on the Icon.

The

Keep key will turn red as soon as any editing of the list

has taken place, indicating that you must press to save the

list.

This key corresponds/is the same, as the

Keep key located

on the Edit page. (see previous page)

Revert
This “Undo” function allows you to revert the to the last

saved SMPTE Event list. This is the List that is stored

locally on the TC Icon.

Clear
Press

Clear to delete the entire SMPTE Event list present

in the TC Icon.

Remote device disk drive

Event lists can easily be organized and saved to a

PCMCIA card in the Mainframe.

Mainframe selection is done in the Auto Edit page.

Get List
Press to get a list of all SMPTE Event lists stored on the

PCMCIA card located in the Mainframe.

New
Press

New to create and name a new Event list on the

PCMCIA card in the Mainframe.

Save
Press to save the current Event list to the card.

Load
Press to load Event list from card.

Delete
Press to delete selected Event preset from the

Event Preset list.

Options

Automation Timecode Options

Master Sync Device
Select which of the Mainframes connected on the LAN you

wish to act as Master Clock.

Start Of Daytime
Range: 23:00:00:.00 or 00:00:00:00

If the SMPTE time code present on your tape media or film

does not start exactly at the beginning of the tape the

23:00:00:00 setting would be a good choice to keep

chronological order in the Event List.