36

paGe Head

frame sysTem - maIn

Single precision:
FADER 1

MIDI CC

70 Sound Controller 1

FADER 2

MIDI CC

71 Sound Controller 2

FADER 3

MIDI CC

72 Sound Controller 3

FADER 4

MIDI CC

73 Sound Controller 4

FADER 5

MIDI CC

74 Sound Controller 5

FADER 6

MIDI CC

75 Sound Controller 6

Double precision, LSB:
(Note that both LSB and MSB must be sent for double precision)

FADER 1

MIDI CC

48 General Purpose Controller #1

FADER 2

MIDI CC

49 General Purpose Controller #2

FADER 3

MIDI CC

50 General Purpose Controller #3

FADER 4

MIDI CC

51 General Purpose Controller #4

FADER 5

MIDI CC

52 Undefined

FADER 6

MIDI CC

53 Undefined

Double precision, MSB
(Note that both LSB and MSB must be sent for double precision)

FADER 1

MIDI CC

16 General Purpose Controller #1

FADER 2

MIDI CC

17 General Purpose Controller #2

FADER 3

MIDI CC

18 General Purpose Controller #3

FADER 4

MIDI CC

19 General Purpose Controller #4

FADER 5

MIDI CC 20 Undefined

FADER 6

MIDI CC

21 Undefined

External MIDI Control - of Fader Parameters

From software version 2.5, all fader assignable parameters can be remote controlled via MIDI Control Change Messages.

To be able to control Faders you must create a dedicated Fader User Group holding these parameters. Page 20 in this

manual section explains how to create User Fader Groups.

Single Precision - Double Precision
We support both single (7bit) and double precision (14 bit) Controller Data, but you should notice that best resolution is

achieved using 14 bit Controller Data. By controlling parameters with Single precision you will be able to control in 128

steps for a complete parameter range. For most applications this will be quite fine and this is also the precision most

external controllers and especially sequencers support. This is called 7 bit precision.

However, System 6000 supports the 14 bit precision standard that has a considerably higher resolution: 128x128=16384

steps.

To achieve this resolution via an external fader control the external controlling device must be able to handle two

controllers at the same time on the same MIDI channel. The scheme below shows which controllers to assign to which

Faders for both Single Precision and Double Precision situations.

MSB value indicates the actual double parameter change. So sending a LSB will not change

the value, but only cache this value for later use when receiving the MSB part.

The LSB must therefore be sent before the MSB.