IP Inputs receive transport streams over UDP/IP from the Ethernet ports, de-jitter them, and
make them available for connections to outputs. The 9220 card supports up to 8 transport stream
inputs per Ethernet port. IP Inputs have the following specifications:

Format support: MPEG-2 Transport Packets over UDP/IP.

Maximum data rate per stream: 120 Mb/s.

Number of MPEG-2 Transport Packets per UDP datagram: between 1 and 7 (no support
for IP fragmentation).

Addressing support: unicast, multicast and broadcast.

Configurable source IP address filtering.

Configurable IP Address/UDP Port redundancy.

IP Inputs: Configuration Tab

The IP Input Configuration follows a similar workflow as the ASI Ports. Ports can be created,
configured, and deleted. Before any ports are created, the Configuration Tab appears as depicted
below:

To create an IP Input stream, first select the desired Ethernet port in the Add Stream drop-down
box. Once that selection is made, the IP Input Stream Configuration is displayed, as depicted
below. The configuration screen has three areas:

Common Parameters: apply to the stream input as a whole, regardless of the
redundancy options.

Redundancy Control: allows selection of the redundancy mode.

Addressing Parameters: allow selection of the network stream to be received