DIP Status
The DIP Status page is used to show the DIP status of SW201 in DT-IPC.
DIP
OFF
ON
1
Reserved
Reserved
2
Other DS
DT591/DT592
3
Local Guard Center
Network Guard Center
4
Door Station
Common Door Station
1
2
3 4
ON
Dip Status page Description
Guard Center: To show the 3rd DIP status of SW201, Local Guard Center or Network
Guard Center. Local Guard Center stands for DIP OFF, press Direct Call Guard Unit button
in the intercom menu of monitor to call monitor who is used as one local guard center.
Network Guard Center stands for DIP ON, press Direct Call Guard Unit button to call Guard
Center, PC station or Guard Station.
DS Work Mode: To show the 2nd DIP status of SW201, DT591/DT592 or other door
station. If it shows DT591, it stands for DIP ON. In this status, when calling the monitor
whose user code is 00/32 by Guard Center or Common Door Station, monitors whose user
codes are in the range of 1 to 15 will respond the calling as slave monitors. If it show other,
no such a function.
Work Mode: To show the 4th DIP status of SW201, Door Station or Common Door Station.
If it shows Door Station, door stations works as a door station, or else, works as a common
door station.