1. Extend platform out to full extension
2. Attached chain binders on each side of probe
3. Slip anchor plates over anchors and bind down each side (figure 22)
Figure 22
Anchoring will limit your side travel somewhat, but you should still be able to take
multiple cores with the anchors installed.
- Do not use extension control while anchors are connected
- Remove the anchors in reverse sequence.
- If anchors have shifted during use and you are unable to slide the hex head of
the anchor back into the hex drive
– use the foot to gently nudge the anchor back
into re-alignment.
Note: Be careful when lowering the probe with the instrument cases in
place. Remove left hand anchor first
– otherwise you might push the head
of the anchor into the instrument mount when lowering probe to remove
RH anchor.