Mechanical, Electrical, Figure 2 – M&C TechGroup MP26-H1 Operator's manual User Manual
Page 10: Dimensions [mm] mp26-h1, 1 mechanical, 2 electrical
10
Gas sampling and gas conditioning technology
6-1.1.15-ME
11.1
MECHANICAL
The dimensions of the mountings are given in figure 1
The pump is provided for assembly and therefore it has to be fastened with screws.
Install the pump so that the fan can draw in sufficient cooling air.
Install the pump so that accidental finger contact with the fan is impossible.
Figure 2 shows the dimensions of the diaphragm pump.
G1/4"
34
ш6
71
300
250
ш11
90
175
60
2
1
3
Dimension in mm
2x PG13, 1x PG9
Heater elements
Thermometer, indicator for 50 - 250°C
Figure 2
Dimensions [mm] MP26-H1
11.2
ELECTRICAL
When making the electrical installation, shown in figure 3, the safety regulations must be observed. In
particular make sure that the electricity supply is isolated before trying to connect the pump.
W A R N I N G !
The diaphragm pumps type MP26-H1 must not be used in hazard-
ous areas.
When connecting the equipment, please ensure that the supply
voltage is identical with the information provided on the model type
plate.
The supply voltage is only allowed to deviate max. +6 % respec-
tively -10% from the indication on the model type plate.