If the ambient temperature in the area of the connections is >80°C as a result of radiated heat, then a
radiated-heat deflector must be mounted to protect the probe.
The connection's mounting flange connection should comply with DN65 PN6. If other connection sizes
are required, a special adapter flange /S010 can be supplied as an option.
Before mounting, the probe must be adjusted to the existing operating conditions. The existing
operational parameters are to be checked accordingly prior to commencing mounting work.
weatherproof mounting position
_____present
_____set
Under / over pressure situation
mbar
bar
Process temperature
°C,
Min.
°C,
Max.
Dust loading
g/m³
Dust composition - grain size
µm
Gas composition
corrosive
toxic
explosive
Which parameters should be
measured, e.g. O
2
, CO, SO
2
, NO
X
,..,
Vol.%
mg/Nm³
ppm
Required amount of gas
l/h,
Min.
l/h,
Max.
Necessary T
90
time
sec.
12
MOUNTING
M&C SP2100-H probes are designed for stationary use and if properly selected and mounted a long
service life and minimum maintenance are guaranteed.
It is advisable to mount the probe in an operational position which is at a 10% inclination to the
process.
Checking the filter element:
Turn the U-bolt at the front end of the filter receptacle several times to the left until the retaining
bolt can also be turned sideways to the left.
Remove the filter receptacle from the probe and check whether the filter element is screwed on
tightly. Replace the filter receptacle
Place the retaining bolt in its original position and tighten the U-bolt.