beautypg.com

EVS XS Version 11.02 - July 2013 Configuration Manual User Manual

Page 95

background image

The following screenshot highlights the Port settings, defined on page 1 of the Channels
tab in the server-based application:

RS422 #1 - #6

Description

Specifies what type of device/controller is connected to each
RS422 port of the EVS server.

Values

The following values can be available if the required license
codes are active:

'EVS Remote' for XSense Remote Panel (code 96)

'EVS IPDP' (code 120 or 121)

'Sony BVW75' (code 118)

'XtenDD35' (code 118)

'Odetics' (and 'Odetics FK)' (code 119)

'VDCP' (and 'VDCP FK)' (code 119)

'EVS AVSP' (code 120 or 121)

'Edit Rec' (code 122)

'LinX' (code 123)

'Touch screen'

Default

On port #1 (only): IPDP

Rules

The following rules are applicable for assigning the following
controlling devices to RS422 ports:

A touch screen can only be assigned to port 6.

Note
Odetics FK and VDCP FK are not available directly from the Port setting, but
when the Odetics or VDCP protocols are assigned to an RS422 port, the Fill and
Key modes are available on the Main Ctrl field in the Channels and Control
settings.

CONFIGURATION MANUAL XS Server 11.02

3. Multicam Configuration

87