Devicenet network scanner dvpdnet-sl – Delta DVP-0204520-03 User Manual
Page 38
DeviceNet Network Scanner DVPDNET-SL
8> In the interface of “Modbus gateway setting”, use the parameters of one slave and fill the relevant
values there. You can refer to the user manual of RTU-DNET.
Note: The slave here is the slave in Modbus network without direct relation with DeviceNet network.
9>
Click on “OK” in the above window and then click on “Download” in the following window to
download the configuration data to RTU-DNET. After download is finished, the configuration
of RTU-DNET is completed.
DVP-PLC Operation Manual