beautypg.com

24 ff – DE DIETRICH MS 24 User Manual

Page 94

background image

94

71.03982.03 - EN

INSTALLATION INSTRUCTIONS

24 FF

Key:

1 Automatic by-pass with check valve

2 Hydraulic pressure switch

3 Three-way valve

4 Three-way valve motor

5 Gas valve with gas diaphragm

6 Gas train with nozzles

7 NTC heating sensor

8 Ignition/flame detection electrode

9 Safety thermostat

10 Water-fumes exchanger

11 Fumes conveyor

12 Fan

13 Venturi tube

14 Positive pressure tap

15 Negative pressure tap

16 Air pressure switch

17 Burner

18 Expansion vessel

19 Pump and air separator

20 Non-return valve

21 Boiler drain tap

22 Pressure gauge

23 Safety valve

24 Disconnector

Figure 19

Heating flow

Gas

DHW

inlet

Heating return

CG_2267 / 1006_2102

Storage

boiler

flow

This manual is related to the following products: