19.1 GAS VALVE CALIBRATION FUNCTION

Note:

The function is automatically deactivated after a period of 15 minutes, at the end of which the electronic board returns to
its operating status prior to the activation of the function or prior to reaching the set maximum temperature.

To simplify calibration of the gas valve, the calibration function may be set directly

on the boiler control panel as follows:

a) hold down the buttons

and

together for at least 6 seconds;

b) after about 6 seconds, the symbols

flash;

c) the display shows, at intervals of one second, “100” and the flow temperature.
In this phase, the boiler works at the maximum heating output (100%).
d) press +/- to immediately set the power of the boiler (100% or 0%);
e) adjust the “Pmax/Pmin” screw (figure 10) to set the burner pressure value as

described in table 1.

To adjust pressure at maximum power, turn the “

Pmax” screw (fig. 10) clockwise

to increase or anti-clockwise to decrease pressure at the burner.

To adjust pressure at minimum power, turn the “

Pmin” screw (fig. 10) clockwise

to increase or anti-clockwise to decrease pressure at the burner.

f) press +/-

to gradually set the desired power level (interval = 1%).

Press the button to leave the function.

0805_2302 / 1002_1201

Consumption 15°C-1013 mbar

24 MI FF - 24 FF

24 - 24 MI

G20

G31

G20

G31

Rated power

2,80 m

3

/h

2,00 kg/h

2,80 m

3

/h

2,04 kg/h

Reduced power

1,12 m

3

/h

0,82 kg/h

1,12 m

3

/h

0,82 kg/h

p.c.i.

34,02 MJ/m

3

46,34 MJ/kg

34,02 MJ/m

3

46,34 MJ/kg

Table 2
* 1 mbar = 10,197 mmH

2

O

Table of burner nozzles

24 MI FF - 24 FF

24 - 24 MI

gas type

G20

G31

G20

G31

diameter of nozzles (mm)

1,28

0,77

1,18

0,77

Burner pressure (mbar*)

REDUCED HEAT OUTPUT

2,0

5,7

2,4

5,6

Burner pressure (mbar*)

RATED HEAT OUTPUT

11,6

32,6

13,8

31,0

Diameter of gas diaphragm (mm)

4,8

5,5

N° nozzles

13

Table 1