INSTALLATION INSTRUCTIONS

• Safety thermostat

Thanks to a sensor placed on the CH flow line, this thermostat interrupts the flow of gas to the burner if the water in

the primary circuit overheats. In these conditions, the boiler is blocked and only after the fault has been eliminated can

it be ignited again by pressing ( ), for at least 2 seconds.

It is forbidden to disenable this safety device

• Flame ionization detector

The flame sensing electrode, located on the right-hand side of the burner, guarantees safety of operation in case of gas

failure or incomplete ignition of the burner.

In these conditions, the boiler is blocked after 3 ignition attempts.

Press ( ), for at least 2 seconds to re-establish normal operating conditions.

• Hydraulic pressure switch

This device allows the main burner to be ignited only if system pressure is higher than 0.5 bars.

• Pump overrun for heating circuit

The electronically-controlled pump post-circulation function lasts 180 seconds and is enabled, in the heating mode, if

the ambient thermostat causes the burner to go out.

• Pump overrun for DHW circuit

The electronically-controlled pump post-circulation function lasts 30 seconds and is enabled, in the DHW mode, if the

probe causes the burner to go out.

• Frost protection device (CH and DHW systems)

The electronic boiler management system includes a “frost protection” function for the heating system which, when

delivery temperature falls below 5°C, operates the burner until a delivery temperature of 30°C is reached.

This function is enabled when the boiler is switched on, the gas supply is open and the system is correctly pressurised.

• Water not circulating in primary circuit (pump probably blocked)

If there is insufficient or no water circulating in the primary circuit, the boiler blocks and the error code E25 is shown on

the display (section 10).

• Anti-block pump function

If no heat demand is received for 24 consecutive hours, in the heating mode, the pump will automatically start and

operate for 10 seconds. This function is operative when the boiler is powered.

• Three-way valve anti-blockage function

If no heat demand is received for a period of 24 hours, the three-way valve performs a complete switching cycle. This

function is operative when the boiler is powered.

• Hydraulic safety valve (heating circuit)

This device is set to 3 bar and is used for the heating circuit.

Connect the safety valve to a drain trap. Do not use it to drain the heating circuit.

N.B.: domestic hot water is guaranteed even if the NTC sensor develops a fault. In this case, temperature is controlled

by the delivery sensor.

23. POSITIONING THE IGNITION AND FLAME-SENSING ELECTRODE

Figure 13

9912070100