20. VISUALISATION OF PARAMETERS ON THE DISPLAY (“INFO” FUNCTION)
Press “
i
” for at least 5 seconds to visualise certain boiler information on the display on the front panel of the boiler.
•
Press buttons (
+/-
) to display the following information:
A00: current DHW temperature (°C);
A01: current external temperature (°C) (with external sensor connected);
A02: modulation current value (100% = 310 mA METHANE - 100% = 310 mA LPG);
A03: power range (%) (MAX R);
A04: heating setpoint temperature (°C) - - If the external sensor is connected, the value of the “kt” curve is displayed
(section 26);
A05: current heating delivery temperature (°C);
A06: DHW temperature setpoint (°C);
A07: — — ;
A08: value (l/minx10) of the DHW flow rate;
A09: last error that occurred in the boiler.
•
This function remains active for 3 minutes. It is possible to interrupt the “INFO” function in advance by pressing button
(
i
) for at least 5 seconds, or turning off the power to the boiler.
N.B:
when the “INFO” function is enabled, the message “A00”, alternating with the boiler delivery temperature,
is shown on the display (figure 12):