beautypg.com

1 remote node bridging setup, And press – ZyXEL Communications PRESTIGE 153 User Manual

Page 113

background image

Prestige 153/153X WAN Bridge/Routers

Bridging Setup

7-3

7.2.1 Remote Node Bridging Setup

Follow the procedure in Chapter 5 to configure the protocol-independent parameters in Menu
11.1 - Remote Node Profile. For bridging-related parameters, you need to configure Menu 11.3 -
Remote Node Network Layer Options.

To setup Menu 11.3 - Remote Node Network Layer Options shown in Figure 7-2, follow these
steps:

Step 1.

In Menu 11.1, make sure the [Bridge] field is set to [Yes].

Step 2.

Move the cursor to the [Edit IP/IPX/Bridge] field, then press the space bar to toggle and
set the value to

[Yes]

, and press

[Enter]

to edit Menu 11.3 - Network Layer Options.

Figure 7-2.

Menu 11.3 - Remote Node Bridging Options

Menu 11.3 - Remote Node Network Layer Options

IP Options:

Rem IP Addr:

Rem Subnet Mask= N/A
My WAN Addr= N/A

Single User Account= N/A

Server IP Addr= N/A

Metric= N/A
Private= N/A

RIP Direction= N/A

Version= N/A

IPX Options:

Dial-On-Query= No

Rem LAN Net #= 00000000
My WAN Net #= 00000000

Hop Count= 1
Tick Count= 2

W/D Spoofing(min)= 3
SAP/RIP Timeout(min)= 3

Bridge Options:

Dial-On-Broadcast= No

Ethernet Addr Timeout(min)= 0

Enter here to CONFIRM or ESC to CANCEL: