Zebra Technologies Z SERIES 79695L-002 User Manual
Page 90
Configuration
Standard Control Panel Parameters
90
79695L-002 Rev. A
Z Series
®
/RZ™ Series User Guide
6/6/08
Select Backfeed Sequence
This parameter sets when label backfeed occurs after a label is removed in
some print modes. It has no effect in Rewind mode. This setting is
superseded by
~JS
when received as part of a label format (see the ZPL
Programming Guide for more information).
Default Value: DEFAULT (90%)
Selections: DEFAULT, AFTER, OFF, BEFORE, 10%, 20%, 30%, 40%,
50%, 60%, 70%, 80%
To change the value shown:
1.
Press
SELECT
to select the parameter.
2.
Press
PLUS (+)
or
MINUS (-)
to scroll through the options.
3.
Press
SELECT
to accept any changes and deselect the parameter.
ZPL, EPL, APL-D
APL-I only
Adjust Label Top Position
This parameter adjusts the print position vertically on the label. Positive
numbers adjust the label top position farther down the label (away from the
printhead) by the specified number of dots. Negative numbers adjust the
position up the label (toward the printhead).
Default Value: +000
Range (ZPL, EPL): -120 to +120
Range (APL-D): –0.64i to 0.64i (when printer is set to operate in inches)
Range (APL-I): –10 to 4000
To change the value shown:
1.
Press
SELECT
to select the parameter.
2.
Press
PLUS (+)
to increase the value.
3.
Press
MINUS (-)
to decrease the value.
4.
Press
SELECT
to accept any changes and deselect the parameter.
APL-I only
Adjust Label Left Position
The label left position adjusts the print position horizontally on the label.
Positive numbers move the left edge of the image toward the center of the
label by the number of dots selected while negative numbers shift the left
edge of the image toward the left edge of the label.
Default Value: +0000
Range: –9999 to +9999
To change the value shown:
1.
Press
SELECT
to select the parameter.
2.
Press
PLUS (+)
to increase the value.
3.
Press
MINUS (-)
to decrease the value.
4.
Press
SELECT
to accept any changes and deselect the parameter.
Table 12 • Printer Parameters (Page 22 of 26)
Language/Parameter
Action/Explanation