beautypg.com

Zebra Technologies Z SERIES 79695L-002 User Manual

Page 82

background image

Configuration
Standard Control Panel Parameters

82

79695L-002 Rev. A

Z Series

®

/RZ™ Series User Guide

6/6/08

Initialize Flash Memory
This option erases all previously stored information from Flash memory.

Caution • This option completely erases the Flash memory.

To initialize Flash memory:

1.

Press

SELECT

to select the parameter.

2.

If prompted for a password, enter the printer password. For
instructions, see

Change Password-Protected Parameters on page 66

.

The display shows

INITIALIZE FLASH?

3.

Press

PLUS (+)

to select

YES

.

The display shows

ARE YOU SURE?

.

4.

Do you want to continue?

• Press

MINUS (-)

to select

NO

to cancel the request and return to the

INITIALIZE FLASH

prompt.

• Press

PLUS (+)

to select

YES

and begin initialization.

When initialization is complete, the control panel displays

INITIALIZING MEMORY COMPLETED

.

Note •

Depending on the amount of free FLASH memory,

initialization may take up to 1 minute to complete.

5.

Press

SELECT

to accept any changes and deselect the parameter.

Print Sensor Profile
A sensor profile shows sensor settings compared to actual sensor readings.
This label (which will extend across several actual labels or tags) can be
used to troubleshoot printing problems. To interpret the results of the
sensor profile, see

Sensor Profile on page 139

.

To print a sensor profile:

1.

Press

SELECT

to select the parameter.

2.

Press

PLUS (+)

to start this standard calibration procedure and print a

media sensor profile.

3.

If the sensitivity of the sensors must be adjusted, perform

Calibrate

Media and Ribbon Sensor Sensitivity on page 83

.

4.

Press

SELECT

to accept any changes and deselect the parameter.

Table 12 • Printer Parameters (Page 14 of 26)

Language/Parameter