Zebra Technologies Z SERIES 79695L-002 User Manual
Page 82
Configuration
Standard Control Panel Parameters
82
79695L-002 Rev. A
Z Series
®
/RZ™ Series User Guide
6/6/08
Initialize Flash Memory
This option erases all previously stored information from Flash memory.
Caution • This option completely erases the Flash memory.
To initialize Flash memory:
1.
Press
SELECT
to select the parameter.
2.
If prompted for a password, enter the printer password. For
instructions, see
Change Password-Protected Parameters on page 66
.
The display shows
INITIALIZE FLASH?
3.
Press
PLUS (+)
to select
YES
.
The display shows
ARE YOU SURE?
.
4.
Do you want to continue?
• Press
MINUS (-)
to select
NO
to cancel the request and return to the
INITIALIZE FLASH
prompt.
• Press
PLUS (+)
to select
YES
and begin initialization.
When initialization is complete, the control panel displays
INITIALIZING MEMORY COMPLETED
.
Note •
Depending on the amount of free FLASH memory,
initialization may take up to 1 minute to complete.
5.
Press
SELECT
to accept any changes and deselect the parameter.
Print Sensor Profile
A sensor profile shows sensor settings compared to actual sensor readings.
This label (which will extend across several actual labels or tags) can be
used to troubleshoot printing problems. To interpret the results of the
sensor profile, see
.
To print a sensor profile:
1.
Press
SELECT
to select the parameter.
2.
Press
PLUS (+)
to start this standard calibration procedure and print a
media sensor profile.
3.
If the sensitivity of the sensors must be adjusted, perform
Media and Ribbon Sensor Sensitivity on page 83
4.
Press
SELECT
to accept any changes and deselect the parameter.
Table 12 • Printer Parameters (Page 14 of 26)
Language/Parameter