Configuration
Change Password-Protected Parameters

66

79695L-002 Rev. A

Z Series

®

/RZ™ Series User Guide

6/6/08

Change Password-Protected Parameters

Certain parameters, including the communication parameters, are password-protected by
factory default.

The first time that you attempt to change a password-protected parameter, the printer displays

ENTER PASSWORD

. Before you can change the parameter, you must enter the four-digit

numeric password. After you have entered the password correctly, you do not have to enter it
again unless you leave Setup mode by pressing

SETUP/EXIT

or by turning off (

O

) the printer.

To enter a password for a password-protected parameter, complete
these steps:

1.

At the password prompt, use

MINUS (-)

to change the selected digit position.

2.

When you have selected the digit that you wish to change, use

PLUS (+)

to increase the

selected digit value. Repeat these two steps for each digit of the password.

3.

After entering the password, press

SELECT

.

The parameter you selected to change is displayed. If the password was entered correctly,
you can change the value.

Default Password Value

The default password value is 1234. The password can be changed using the Zebra
Programming Language (ZPL) command

^KP

(Define Password) or using the printer’s web

pages (ZebraNet

®

10/100 Print Server or Wireless Plus Print Server required).

Disable the Password Protection Feature

You can disable the password protection feature so that it no longer prompts you for a
password by setting the password to 0000 via the

^KP

ZPL command. To re-enable the

password-protection feature, send the ZPL command

^KPx

, where

x

can be any number from

1 to 9999.

Caution • Do not change password-protected parameters unless you have a complete
understanding of the parameters’ functions. If the parameters are set incorrectly, the printer
may function unpredictably.