Calibration problems – Zebra Technologies Z SERIES 79695L-002 User Manual
Page 122
![background image](/manuals/228909/122/background.png)
Troubleshooting
Calibration Problems
122
79695L-002 Rev. A
Z Series
®
/RZ™ Series User Guide
6/6/08
Calibration Problems
identifies problems with calibration, the possible causes, and the recommended
solutions.
Table 18 • Calibration Problems
Problem
Possible Cause
Recommended Solution
Loss of printing
registration on labels.
Excessive vertical
drift in top-of-form
registration.
The platen roller is dirty.
Clean the platen roller according to the
instructions in
Clean the Printhead and Platen
.
Media guides are positioned
improperly.
Ensure that the media guides are properly
positioned.
The media type is set
incorrectly.
Set the printer for the correct media type
(gap/notch, continuous, or mark). See
The media is loaded incorrectly.
Load media correctly. See
.
Auto Calibrate failed.
Media or ribbon is loaded
incorrectly.
Ensure that media and ribbon are loaded
correctly.
The sensors could not detect the
media or ribbon.
Manually calibrate the printer. See
Media and Ribbon Sensor Sensitivity on page 83
.
The sensors are dirty or
positioned improperly. The
sensors are dirty, or media is
positioned improperly for the
sensors to detect.
Ensure that the sensors are clean and that media
is positioned properly.
The media type is set
incorrectly.
Set the printer for the correct media type
(gap/notch, continuous, or mark). See