Step 3: globally enable power modules outputs (global on)
First operation steps
Global enable
Press the
OUT
key to toggle the state of the global output enable feature (turn the
power supply system ON and OFF).
You can verify the state of the global enable feature by looking at the out indicator
located next to the OUT key: when the indicator is on – outputs are globally
enabled.
For a power module to provide power at its output, all the following
conditions must be met:
The Main Converter is operating.
The power modules are globally enabled (global on).
The Power Module is turned on (individually enabled).
The Power Module does not report any fault.
The output disconnect relay is closed.
cont
Global
on/off
relay
on/off
out
ok
Converter
mains
Illustration of conditions needed for producing an output
You can select an active power module (one that is individually enabled [turned on])
and view its output values. Please refer to the “Using the front panel” chapter.