Configuring the gpib link, Ctivating the, Gpib – Xantrex Technology XMP 2600 User Manual
Page 103: Link, Hat is displayed, Ow to, Temporarily, Activate, Or disable, Gpib 84
![background image](/manuals/228165/103/background.png)
Configuring the GPIB link
Power Supply setup
Configuring the GPIB link
The GPIB communication link is used for remotely controlling the XMP 2600
power supply system.
Activating the
GPIB link
Activation of the GPIB communication link is done with the dip switches located at
the back of the XMP’s master mainframe but it can also be, temporarily, activated
using the front panel.
What is displayed
The following illustration shows the way the GPIB communication link is activated
(or disabled):
GPIB activation
selection
system
symbol
system
parameters to set
condensed
modules status
Setup mode display – GPIB link activation
How to, temporarily, activate (or disable) the GPIB
To control the state of the GPIB link proceed as follows:
Make sure the display is in setup mode.
Move the cursor (using the LEFT / RIGHT selection keys) to the GPIB
parameter.
Using the UP / DOWN selection keys change the state of the GPIB link
to one of the following:
o “GPIB = NO” to disable the GPIB communication link.
o “GPIB = YES” to activate the GPIB communication link.
Selecting this state, automatically changes the display to the GPIB
setup mode.
Setting GPIB
parameters
The GPIB bus address of the XMP 2600 is set using the dip switches located at the
back of the XMP’s master mainframe but it can also be, temporarily, set using the
front panel.
Other GPIB parameters are set using the front panel.
What is displayed
The following illustration shows the display layout when setting up the GPIB
parameters:
84
XMP 2600 User’s Guide
rev. 1.0