Western Telematic SRM-100 User Manual
Page 53

Register
Range
Default
Function
S95
---
000
Extended Result Codes. The bits in this register can be set to override some
of the Wn command options. A bit set to 1 in this register will enable the
corresponding result code regardless of the
Wn setting.
Bit
Dec Value
Function
0 =
1
CONNECT CODE indicates DCE speed instead of
DTE speed.
1 =
2
Append /ARQ (Automatic Repeat Request) to
verbose CONNECT XXXX result code if protocol is
other than none.
2 =
4
Enable CARRIER XXX result code.
3 =
8
Enable PROTOCOL XXXX result code.
5 =
32
Enable COMPRESSION result code.
Note: To enable more than one function, add up the decimal values of the
desired functions. For example, to enable CARRIER, PROTOCOL, and
COMPRESSION, you would add 32 + 8 + 4 for a total of 44. Therefore, the
command to enable these functions would be ATS95=44.
10-7
SRM-100 - Secure Rack Modem, User's Guide
S-Registers