beautypg.com

Logged events – TANDBERG Gatekeeper User Manual

Page 60

background image

TANDBERG Gatekeeper User Guide

Page 60 of 105

14.5.

Logged Events

Events logged at level 1

Event

Description

Eventlog Cleared

An operator cleared the event log.

Admin Session Start

An administrator has logged onto the system.

Admin Session Finish

An administrator has logged off the system.

System Configuration
Changed

An item of configuration on the system has changed.
The

Detail

event parameter contains the name of the changed

configuration item and its new value.

Policy Change

A policy file has been updated.

Registration Requested

A registration has been requested.

Registration Accepted

A registration request has been accepted.

Registration Rejected

A registration request has been rejected.
The

Reason

event parameter contains the H225 cause code.

Optionally, the

Detail

event parameter may contain a textual

representation of the H.225 additional cause code.

Registration Removed

A registration has been removed by the Gatekeeper/Border

Controller.

The

Reason

event parameter specifies the reason why the

registration was removed. This is one of:

Authentication change

Conflicting zones

Operator forced removal

Operator forced removal (all registrations removed)

Call Answer Attempted

An attempt to answer a call has been made.

Call Attempted

A call has been attempted.

Call Connected

A call has been connected.

Call Disconnected

A call has been disconnected.

Call Rejected

A call has been rejected.
The

Reason

event parameter contains a textual representation of

the H.225 additional cause code.

Call Bandwidth Changed

The bandwidth of a call has changed.