SYSTEM FUNCTIONS
8-11
In addition, Expert level includes these commands:
numbase
Set default number base to either decimal,
hexadecimal, binary or none. If none is
selected all numbers must be preceded by
explicit specifiers.
The default base can always be overridden
by explicit specifiers:
%
for binary
$
for hex
#
for decimal numbers.
t
DEEP TECH NOTE!
Numbase is provided for users who want to write their own control software. It
affects only the remote control function: the displays remain in decimal at all
times.
oscill
Switch on/off test tone oscillator on both
mic inputs.
parport
none
[
example
parport val3
¶
Display parallel contact closure status.
Sets the four parallel contacts to match the
bit pattern and ignore incoming ancillary
data.
Restores normal operation.
Sets contacts to off-on-on-on.
reset
[cold|res]
Reset the system by restarting the code
without physical reset. cold will wipe out
all user-defined system parameters and
setups. res will maintain user settings.
We may ask you to enter some other
arguments during a support call.
rtcset
Set date and/or time of RTC (real time
clock).
switch
Return information about internal and
backpanel switches.