SYSTEM FUNCTIONS

8-9

t

DEEP TECH NOTE!

Remote control values for LCD contrast and backlighting are only vaguely
related to the 0-100% settings in the

System

menu.

level

none

Display current encoder input & decoder
output level, for testing the meter
calibration.

log

[

]

Used for remote debugging. During a
support call, we may ask you to send this
command and tell us what the result is.

login

[ |

]

Example

login user

Display current security level.

Unlock at the security level associated with
this password.

Opens communication at User level.

logout

none

Log out from ZephyrExpress control
system.

metertest

none

[<0...9 0...9 0...9

0...9>]

Resets front panel level meters to normal
operation after a test.

Turns on the four level meter LEDs up to
the number indicated, for lamp testing.

If you’re going to specify an argument, you
must supply numbers for all four meters:

metertest

9 9 would be rejected.

Example

metertest 9 9 9 9

Lights up all four metersas if they were
indicating a signal at -10dB.

mic

<1|2|both> [

] |

[

linesense>]

Example

mic 2 highf on

Switches microphone phantom power or
highpass filter on or off, or sets mic
sensitivity.

Turns on the highpass filter for mic 2.

mop

none

[

l2mo64|l2mo128|l2du|

l2jo|->]

[]

Displays the current codec mode (using the
codes below).

Sets the transmit mode to L3-dual or L3-
stereo or L3-joint or G.722 or L2-mono64
or L2-mono128 or L2 dual or L2-joint. If
the parameter is sent as “–”, the current
transmit mode is kept.

Sets the receive mode to L3-stereo or L3-
mono or G.722 or L2. If the parameter is
sent as “–”, the current receive mode is