Chapter 3 Operation

IPmux-16 Installation and Operation Manual

3-42 Configuring IPmux-16

Table 3-3. Alarms and Statistics (Cont.)

Alarm

Failure

Comments

Valid in X only

SES

Severely Errored Seconds.

Any second containing the
following errored events is
counted as severely errored
seconds:

For

E1/T1:

If 320 or more CRC error events
One or more SEF (OOF) events

One or more AIS events
occurred (for T1 only).

UAS

Unavailable Seconds:

Activated when there are 10
consecutive SES occurrences
and
Deactivated as a result of 10
consecutive seconds without
SES.

LOMF

Loss Of Framing sequence in
Time Slot 16

The E1/T1 Physical Layer Menu allows you to monitor the following
Time Since

: The elapsed time since the beginning of the current interval

(interval 0). Displayed only when the current interval is monitored.

Valid Intervals

: The number of 15 minute intervals stored in the system since

power up.

Slot/Channel:

Select the E1/T1 module and channel on which you want to view

statistics

Interval Number

: The number of the interval to be displayed.

Interval number 0 (zero) is the current interval.

The current interval display is continuously updated.

The elapsed time since the beginning of the interval is displayed.

Prev Inv:

Displays the previous interval.

From the first interval (current interval = 0) Prev is not visible

Next Inv:

Displays the next interval.

The number of valid intervals is displayed.
From the last valid interval Next is not visible.