Ascii terminal configuration – RAD Data comm TDMoIP Gateway IPmux-16 User Manual
Page 49

IPmux-16 Installation and Operation Manual
Chapter 3 Operation
Configuring IPmux-16
3-17
Table 3-2. IPmux-16 Alarms (Cont.)
Alarm ID
Alarm Description
Trap Sent to NMS
Dry Contact
21
Far End Block Error (FEBE Line Layer) Alarm FEBE
1.3.6.1.4.1.164.6.1.3.0.12
Major
26
Local Connectivity Fail
Local Conn Status Trap
1.3.6.1.4.1.164.6.1.3.0.13
Minor
27
Remote Connectivity Fail
Remote Conn Status Trap
1.3.6.1.4.1.164.6.1.3.0.14
Minor
All other Alarms are unused.
ASCII Terminal Configuration
Main Menu
↓
2. Configuration
↓
1. General
Configuration
↓
2. ASCII Terminal
Config
.
➤
To configure the ASCII terminal
• Type 2 (ASCII Terminal Config.) in the General Configuration menu.
ASCII Terminal Configuration
1. Display Mode Color
2. Baud Rate [bps] 19200
3. Change Password
4. Hard flow ctrl (RTS/CTS) Off
ESC. Exit
Select item from the menu:_
Figure 3-18. The ASCII Terminal Configuration Menu
Display Mode:
Color / MonoChrome 3 color / MonoChrome 2 color
Baud Rate
9600 / 19200 / 38400 / 57600 – in units of bps
Default:
19200
Change Password
Choose this option to enter a menu that allows the
user to change the current password
Hard flow ctrl
Set the 15 minute timeout to On or Off
When On the terminal will exit to the password screen
if no characters were sent by the terminal for
15 minutes.