Chapter 3 Operation

IPmux-16 Installation and Operation Manual

3-40 Configuring IPmux-16

Table 3-3. E1/T1 Alarms and Statistics

Alarm Failure Comments

LOS

Loss of Signal

Sync LED Off.

For T1: A second during which 192 contiguous pulse positions have no
pulse of either positive or negative polarity (signal is more than 30 dB
below nominal amplitude.

For E1: A second during which 255 contiguous pulse positions have no
pulse of either positive or negative polarity.

LOF

Loss of Frame Sync LED off.

For E1/T1: A second during which an OOF (see below) error persists for
2.5 seconds and no AIS error (see below) is detected.

LCV Line

Code

Violation

Line Code Violation
For T1: A second during which BPV (Bipolar Violation) or EXZ errors have
occurred.

For E1: A second during which two consecutive BPVs of the same
polarity are received.

BPV is the occurrence of a pulse with the same polarity as the previous
pulse.

EXZ is the occurrence of a zero string greater than 15 for AMI or 7 for
B8ZS.

Complies with ITU-TI.431, 0.161, G.775 and G.821 standards.

Rcv RAI
(Yellow
Alarm)

Remote
Alarm
Indication

The Sync LED flashes.

For E1/T1, a second during which an RAI pattern is received from the far
end when the far-end framer enters a RED state (Loss of Frame).

AIS Alarm

Indication
Signal–
Received
from User

The Sync LED is off.

For T1: A second during which an unframed “all 1” signal is received for
3 milliseconds.

For E1: A second during which a string of 512 bits contains fewer than
three zero (0) bits.