IPmux-16 Installation and Operation Manual

Chapter 3 Operation

Configuring IPmux-16

3-41

Table 3-3. Alarms and Statistics (Cont.)

Alarm Failure

Comments

Valid Modes

FEBE

Far End Block Error

The number of seconds in which
the FEBE indication is received
from the remote E1 device.

E1 CRC4 mode

BES

Bursty Errored Seconds (Errored
Second type B)

The number of seconds with
from two to 319 CRC error
events with no AIS nor SEF
(Framing Bit Errors) error
detection.
Not applicable if Line Type is set
to Unframed

T1-ESF or
E1-CRC4 modes

DM

Degraded Minutes

A Degraded Minute is calculated
by collecting all of the available
seconds, subtracting any SESs
and sorting the result in 60
second groups.
A Degraded Minute is a 60
second group in which the
cumulative errors during the
60-second interval exceed
1x10

-6

.

T1-ESF or
E1-CRC4 modes

ES

Errored Second: If any error
occurs during one second.

Any second containing the
following error events:
CRC

SEF (OOF)
AIS (T1 only).
If SES is also active (see below)
ES runs for 10 seconds and then
stops (T1 only).