IPmux-16 Installation and Operation Manual

Chapter 3 Operation

Configuring IPmux-16

3-27

When “unframed” mode is selected, the Idle Code, Signaling Mode, Cond Data

Pattern and Cond CAS Pattern fields are not present.

When CAS Disabled is selected, the Cond CAS Pattern field is not present.

To change the source of the transmit clock:
• Type 1 and press the <Spacebar> on your keyboard to toggle between

Adaptive/Loopback/Internal/External.

Adaptive: Adaptive

clock

regeneration

Loopback:

The E1 recovered receive clock is used as the transmit clock.

Internal:

A local clock source is used.

Default value: Adaptive

To change the Loopback State setting:
Refer to Chapter 4 for detailed instructions on loopback tests.

To change the RX Sensitivity setting:
• Type 3 and press the <Spacebar> on your keyboard to toggle between

–10 dB / –32 dB. This setting determines the maximum attenuation of the
receive signal that can be compensated for by the interface receive path.

Default value: E1: -10 dB

To change the Line Type setting:
• Type 4 and press the <Spacebar> on your keyboard to toggle between CRC4

Enable / CRC4 Disable / UNFRAMED. This setting determines the framing
mode and operation mode for each configuration.
− Unframed: Framer will be configured to pass through mode and the

operation mode will be set to Unframed (see Chapter 1, section 1.3).

− CRC4 Enable: Framer will be configured to CRC4 MF mode. Operation

mode will be set by Signaling Mode field #6 to either Fractional or
Fractional with CAS (see Chapter 1, section 1.3).

− CRC4 Disable: CRC4 MF mode is disabled. Operation mode will be set by

Signaling Mode field #6 to either Fractional or Fractional with CAS (see

Chapter 1, section 1.3).

Default

value:

CRC4 enabled

Changing the Line Type setting will delete all connections.

To determine the idle code inserted into unused time slots by IPmux-16-E1 at
the transmit path towards E1 equipment:
• Type 5 (Idle code) and enter a new value.

(This field will not appear if “unframed” is selected in the Line Type field.)
Range: 00-FF

Default value: 7E

Note

Note