RAD Data comm TDMoIP Gateway IPmux-16 User Manual
Page 53

IPmux-16 Installation and Operation Manual
Chapter 3 Operation
Configuring IPmux-16
3-21
6. Enter
S
to save the parameters and start the transmission process. If all
parameters are correct, you will be asked for confirmation. Transmission
begins only after confirmation.
7. Enter
6
to enter a User file name.
8. Enter
7
to view the transfer status in real-time; the View Transfer Status
window is displayed.
VIEW TRANSFER STATUS
Status Transferring
Data
Error
No Error
ESC. Exit
Figure 3-23. View Transfer Status Window
The View Transfer Status window is updated every second. The screen is read-only
with these possible options:
• Status indication possibilities are:
− No Operation
− Connecting
− Transferring Data
− Ended on Time Out
− Ended OK
− Error.
• Error message possibilities are:
− Unavailable (no host IP)
− No Error
− File Not Found
− Illegal TFTP Operation
− Unknown Transfer ID
− Illegal PDU Size
− Illegal File Mode
− No Empty Connection
− No Empty UDP Port
− Server Overflow.
After confirmation, the TFTP session will begin.