Thinning out the sequencer data (data thin), Data thin->p. 190, 190 editing songs – Roland X-6 User Manual
Page 190
190
Editing Songs
Bias
Specify the amount (number of ticks) by which the sequencer data
will be moved.
Value:
-4800– +4800
Status
Selects the type of data to be shifted in time.
Value
ALL
NOTE
Polyphonic Aftertouch
Control Change
Program Change
Channel Aftertouch
Pitch Bend
System Exclusive
Tune Request
Pattern Call
If the Track parameter is set to “TEMPO,” the Status parameter
will not be available.
Range Min, Range Max
If you set the Status parameter to “NOTE,” “P.AFT,” “C.C,” or
“PROG,” specify the range of data. Set “Range Min” to the lowest
value of the range, and “Range Max” to the highest value of the
range.
To shift all notes or polyphonic aftertouch data, set “Range
Min” to “C -1” and “Range Max” to “G9.” To shift C4, set
“Range Min” and “Range Max” to “C4.” To shift C3 through
C4, set “Range Min” to “C3” and “Range Max” to “C4.”
• To shift all controller numbers, set “Range Min” to “0” and
“Range Max” to “127.” To shift all program numbers, set
“Range Min” to “1” and “Range Max” to “128.” To shift number
4, set “Range Min” and “Range Max” to “4.” To shift numbers 3
through 14, set “Range Min” to “3” and “Range Max” to “14.”
Continuously variable controllers such as aftertouch, pitch bend, and
expression tend to create unexpectedly large amounts of data when
operated. Data Thin will strip out redundant data to increase the
amount of memory available for the sequencer.
fig.19-022_50
For details on the settings, refer to
Track / Pattern (Source Track)
Specifies the track(s) or pattern whose sequencer data will be
thinned.
Value
ALL:
Phrase tracks 1–16, the beat track, and the tempo
track
TRK 1–TRK 16:
The specified phrase track
PTN001–PTN100:
The specified pattern
Ch / Part
Selects MIDI channel of the data to be thinned.
To thin all sequencer data, set this parameter to ALL. To thin
sequencer data of just one specific MIDI channel, select that MIDI
channel.
Value:
ALL, Ch1–Ch16
Measure, For (Edit Range)
Specifies the range of measures whose sequencer data will be
thinned. If you set “For” to “ALL,” all measures will be specified.
Data Thin Value
For thinning data which incorporates rapid changes, use higher
settings. If you don’t want to thin that much data even though it is
subject to rapid change, use lower settings.
Data Thin Time
If you are thinning data that changes gradually over time, use higher
settings. If you don’t want to thin that much data even though the
changes are gradual, use lower settings.
Thinning Out the Sequencer Data
(Data Thin)
Fantom-X678_r_e.book 190 ページ 2007年3月20日 火曜日 午前10時20分