Troubleshooting, 1 flowchart to remedy the troubles – Renesas M3028BT-EPB User Manual
Page 80
M3028BT-EPB User’s Manual
5. Troubleshooting
REJ10J1459-0200 Rev.2.00 Sep 16, 2006
5. Troubleshooting
This chapter describes how to troubleshoot when this product does not work properly.
5.1 Flowchart to Remedy the Troubles
Figure 5.1 shows the flowchart to remedy the troubles from when power to the emulator is activated until the emulator
debugger starts up. Check this while the user system is disconnected. For the latest FAQs visit the Renesas Tools Homepage.
http://www.renesas.com/en/tools
Turning on PC7501
Front panel LED
of PC7501
1. Check emulator system connections.
See, "2.5
Connecting the Power Supply for the Emulator"
(page 24).
2. Redownload the firmware.
See "2.7 Downloading Firmware" (page 27).
3. Restart the PC7501 system.
Init dialog box of
emulator debugger displayed
1. Check the operating environment etc. of the
emulator debugger.
See the user's manual of the emulator debugger.
2. Reinstall the emulator debugger.
MCU Setting dialog box
of emulator debugger displayed
See "5.2 (2 ) MCU Setting Dialog Box Does Not Appear at
Debugger Startup" (page 80)
Editor window of
emulator debugger displayed
See "5.2 (3 ) Errors Occur at Debugger Startup" (page 81)
Emulator debugger startup completed
Normal
Normal
Normal
Normal
Not normal
Not normal/Error displayed
Not normal/Error displayed
Error displayed
Figure 5.1 Flowchart to remedy the troubles
Page 78 of 86