Chapter 5 Packet capture 123
Nortel VPN Router Troubleshooting
To create and use this capture object, you run commands like the ones illustrated
in this example. These commands do the following:
1
Create a capture object called test-trigger on Fast Ethernet interface 0/1.
2
Enter Capture Configuration mode for the object.
3
Set the start trigger to permit FTP.
4
Set the stop trigger to permit Telnet.
5
Exit Capture Configuration mode.
6
Start the capture.
CES#
capture add test-trigger fastethernet 0/1
CES#
capture test-trigger
CES(capture-ethernet)#
trigger start "permit FTP"
CES(capture-ethernet)#
trigger stop "permit Telnet"
CES(capture-ethernet)#
exit
CES#
capture test-trigger start
CES#
To view the status of the running capture object, as well as its configuration, use
the
show capture
command. In this example, you can see that:
•
The captured frames field indicates that the capture was triggered by the
receipt of FTP traffic.
•
The start trigger discards field shows the number of packets discarded before
the start trigger was activated by the receipt of FTP traffic.
CES#
show capture test-trigger
Capture state: RUNNING
Capture buffer size: 1048576
Capture type: ETHERNET
Capturing on interface: FastEthernet 0/1
Promiscuous mode is: DISABLED
Capturing MAX octets per frame: 4096
Captured frames: 107
Capture buffer utilization: 0%
Capturing direction: BIDIRECTIONAL
Capture buffer wrapping: DISABLED
Capture buffer wrapped: FALSE
Start trigger applied: permit FTP
Start trigger discards: 362
Stop trigger applied: permit Telnet
CES#