Programming overview (profiles 2 and 3), Programming overview (profiles 2 and 3) 6, Maintenance – Nortel Networks ICS 6.1 User Manual
Page 14: Usage metrics, Profile, Dialpad, Startup, Terminals&sets, Lines
6
Modular ICS 6.1 Programming Record
P0603536 02
Config
Ptl
V.35
DS0 rate
64k
TxClk src
Auto
TxClk invrsn
Off
Data invrsn
Off
Fixed access
Show line:_
L001:
Unassigned
L001:
Channel:xx
Lp state
None
Lpbk
Off
Cd2-KSU
Loop
Mod 03 to 08
StnMod
System version
Port/DN status
Module status
Sys test log
Sys admin log
Network evt log
Provisioning
Tests
CSU stats
Diagnostic tools
Link status
Usage Metrics
Hunt groups
Call-by-Call
PROF 1
Q, Z:0
Template
(MICS)
Square/(XC)PBX
Start DN
221
Show set:_
Line access
Line assignment
Show line:_
(If it is a Non-DID line)
L001
Unassigned
(If it is a DID line)
L001
1
LinePool access
LinePool A
Y
(if there are PRI pools)
LinePool PRI-A
N
Prime line
I/C
Intercom keys
2
Answer DNs
Show set:_
222
Unassigned
OLI#
None
Capabilities
Fwd no answer
Fwd to
None
Forward delay
4
Fwd on busy
Fwd to
None
DND on Busy
N
Handsfree
None
HF answerback
Y
Pickup grp
None
Page zone
1
Paging
Y
D-Dial
Set1
Priority Call
N
Hotline
None
(if Hotline=Extrnl and number
specified )
Use prime line
Aux. ringer
N
Allow redirect
N
Redirect ring
Y
Intrusion
Protect Lvl
None
ATA settings
ATA ans timer
7
ATA use
Off site
Msglndicate
None
ATA dvc
Modem
SM Supervisor
N
Name
221
User prefernces
Mdl
M7208
Button prgrming
User speed dial
(256-279)
Call log opt’ns
No one answered
Dialing opt’ns
Standard dial
Language
English
Display cntrst
4
Ring type
1
Restrictions
Restrn filters
Show filter: _
Restn flt 00
No restrictions
Restrn flt 01
Restrn 01
Deny
0
No overrides
Set restrns
Filters
Normal
02
Night
11
Evening
12
Lunch
13
Sched 4
00
Sched 5
00
Sched 6
00
Set lock
None
Allow last no
Y
Allow saved no
Y
Allow link
Y
Line/set rstrns
Show line:_
Normal
None
Night
None
Evening
None
Lunch
None
Sched 4
None
Sched 5
None
Sched 6
None
Telco features
Feature Assignment
Show line:_
Caller ID set
N
Extl VMsg set
N
1st Display
Name
Called ID
N
Log space
Log
0
Pool
600
Show line:_
Trunk/Line data
(If Target Line)
Line type
Public
Rec’d #
None
PrimeSet
221
Distinct Ring
None
Aux. ringer
N
If busy
PrimeSet
(If PRI Lines (001 to 030, 031 to 060)
Profile 2 only
Trunk Type
PRI
Line type
PRI-A
PrimeSet
221
Distinct Ring
None
(If T1 and Loopstart) Profile 3 only
Trunk Type
Loop
Line type
Pool A
Dial mode
Tone
PrimeSet
221
Distinct Ring
None
Auto privacy
Y
Trunk mode
Unspr
Ans mode
Manual
Ans with DISA
Y
Link at CO
(analog only)
N
Aux. ringer
N
Full AutoHold
N
LossPkg
MediumCO
(If T1 and Groundstart) Profile 3 only
Trunk Type
Ground
Line type
Pool A
Dial mode
Tone
PrimeSet
221
Distinct Ring
None
Auto privacy
Y
Ans mode
Manual
Ans with DISA
Y
Aux. ringer
N
(If T1 and E&M) Profile 3 only
Trunk Type
E&M
Line type
Pool A
Dial mode
Tone
PrimeSet
221
Distinct Ring
None
Auto privacy
Y
Ans mode
Manual
Ans with DISA
Y
Aux. ringer
N
Signal
Winkstart
ANI number
N
DNIS number
N
Gain
Normal
Programming overview (Profiles 2 and 3)
Defaults are shown in bold and underlined