Behavior at occurrence of error, Post error messages – NEC Express 5800/320Lc User Manual
Page 68
2-34 General Description
7.
Upon completion of POST, the password entry screen appears prior to OS startup.
The password entry screen will appear after the normal termination of POST only if you
have set a password in the BIOS setup utility “SETUP.”
You can enter a password up to three times. If you enter an incorrect password three times,
the startup will be unsuccessful. In this case, turn off the power and then turn it on again
after waiting 30 seconds to boot the server.
IMPORTANT:
Do not set a password before installing the OS.
8.
Upon completion of POST, the OS will start up.
Behavior at Occurrence of Error
If POST or OS startup does not finish normally, the server will reboot itself automatically.
At the time of reboot, it will select the other CPU/PCI module and run POST or OS startup.
In this manner, the server retries POST or OS startup with different combinations of CPU/PCI
modules. If POST does not finish normally with any combinations, the server will stop with the
state of DC OFF.
While performing retries, the server displays or registers the error types.
For details of error messages, see Chapter 7 “Troubleshooting.”
POST Error Messages
When the server detects an error during POST, it will notify you of the occurrence in the following
manners:
Displays an error message on the display unit.
Displays an error message on the LCD*.
Makes a beeping sound.
*For details, see “Error Messages on the Liquid Crystal Display (LCD)” in Chapter 7.
These notification methods are described in “POST Error Messages” in Chapter 7.
IMPORTANT:
Before you contact your sales agent, write down the error messages and
patterns of the beeping sound. They will serve as helpful information at the time of
maintenance.