beautypg.com

Switch and strap settings, Signal ground – Northern UTA220/UTA220k User Manual

Page 26

background image

3-2

UTA220/UTA220k

Getting Started

Figure 3-1. Cover Removal

To replace the cover, align the lock clips, rear guide grooves,
and front lock tabs. Press the cover in place until the lock
prongs engage the lock clip.

SWITCH AND STRAP SETTINGS

The following options are selected by switches or straps
located on the PC boards inside the UTA220 housing. To
change the strap setting, lift the jumper strap connector off and
reinsert it in the new position. Figure 3-2 shows a typical strap
application.

Figure 3-2. Typical Strap Application

Caution: Only personnel familiar with DIP switch selection
should change switch positions or the ground strap from
factory settings. Changes should be made only during setup.

Signal Ground

Signal ground is normally isolated from frame ground
(factory). If interference exists, connect signal ground to frame
ground by moving the strap.