beautypg.com

Printronix P9000 Series User Manual

Page 172

background image

Interfaces

7-2

Data Strobe - A high true pulse from the host to indicate that data is ready. The data strobe

must remain high at least until the Data Request line goes false.

Data Lines - Eight standard or inverted levels from the host that specify character data, plot

data, or a control code. Sensing Data Line 8 is controlled by printer configuration.

Paper Instruction (PI) - Optional standard or inverted level VFU signal from the host with

the same timing and polarity as the data lines. PI line sensing is controlled by printer configuraĆ

tion.

NOTE: The PI Line must be disabled (configuration option selected from the front

panel) if the host computer does not drive or control the PI Line. If the line is not conĆ

trolled by the host and sensing is enabled, rapid paper slewing will occur.

Interface Verification - Two pins on the interface connector jumpered together allow you to

verify proper installation of the interface connector.

NOTE: The +5 volt test is only connectable with a jumper.

Table 7-1. Connector Pin Assignments for

Dataproducts Interface with AMP Connector

SIGNAL

PIN

SIGNAL

PIN

Data Line 1

Data Line 2

Data Line 3

Data Line 4

Data Line 5

Data Line 6

Data Line 7

Data Line 8

Paper Instr.

Data Strobe

Return

Return

Return

Return

Return

Return

Return

Return

Return

Return

Ready

On Line

I/F Verif.

Return

Data Request

19

3

20

4
1

2

41

40
34

18
43

42
36

35
28

44

30

14

38

37

22

6

21

23

45, 46

Return

5

Return

7

OUTPUT

INPUT

Return

39

Pins not listed are not connected.