beautypg.com

Bit image mode, quadruple density – Printronix P9000 Series User Manual

Page 110

background image

Programming

6-12

Bit Image Mode, Quadruple Density

ASCII

Hex

Decimal

P-Series

N/A

N/A

N/A

Serial

ESC Z

1B 5A

27 90

Purpose

Selects Quadruple Density Bit Image graphics.

Expression

CHR$(27);”Z”;CHR$(n1);CHR$(n2);”DATA”

where

n1 + 256 n2 define the number of data bytes to follow.

DATA = ASCII characters for the dot pattern bytes.

NOTE: The DATA can be expressed in a CHR$(DATA) format with the appropriate

decimal values of the ASCII characters supplied especially in cases where the dot patĆ

terns of nonprintable characters are required.

Comment

Quadruple Density printing may reduce print speed to half. For detailed inĆ

formation, refer to the Bit Image section in the Graphics chapter.

The printed density in this mode is 120 dpi horizontal and 72 dpi vertical when

selected from the Data Processing print mode or 180 dpi horizontal and 96 dpi

vertical when selected from the Correspondence print mode.

Example

The following example produces quadruple density graphics of the pattern

used in the Single Density Bit Image Mode example. Note that the amount of

data must be quadrupled for quadruple density (the data is used 108 times

rather than 27).

NOTE: Depending on the host computer system, it may be necessary to include a width

statement within the BASIC program.