8 basic tcp/ip Page 96
Page 96
Administrator Guide - SoundPoint
®
IP / SoundStation
®
IP
Optimization
88
Copyright © 2004 Polycom, Inc.
4.6.1.7.2.2 Call Control
These parameters apply to call control packets, such as the network protocol signaling.
4.6.1.8 Basic TCP/IP
4.6.1.8.1 Network Monitoring
Do not alter these values.
4.6.1.8.2 Time Synchronization
The following table describes the parameters used to set up time synchronization and
daylight savings time. The defaults shown will enable daylight savings time for
North America.
Daylight savings defaults:
• don’t use fixed day, use first or last day of week in the month,
• start DST on the first Sunday in April at 2 am,
Attribute
Permitted
Values
Default
Interpretation
qos.ip.callControl.min_delay
0, 1
1
If set to 1, set min-delay bit in
the IP TOS field of the IP
header, or else don’t set it.
qos.ip.callControl.max_throughput
0, 1
0
If set to 1, set max-throughput
bit in the IP TOS field of the IP
header, or else don’t set it.
qos.ip.callControl.max_reliability
0, 1
0
If set to 1, set max-reliability bit
in the IP TOS field of the IP
header, or else don’t set it.
qos.ip.callControl.min_cost
0, 1
0
If set to 1, set min-cost bit in the
IP TOS field of the IP header, or
else don’t set it.
qos.ip.callControl.precedence
0-7
5
If set to 1, set precedence bits in
the IP TOS field of the IP
header, or else don’t set them.
Attribute
Permitted Values
Default
tcpIpApp.netMon.enabled
0, 1
1
tcpIpApp.netMon.period
1 to 86400
30