1 basic logging and Page 112
Page 112
Administrator Guide - SoundPoint
®
IP / SoundStation
®
IP
Optimization
104
Copyright © 2004 Polycom, Inc.
Each event in the log contains the following fields separated by the | character:
• time or time/date stamp
• 1-5 character component identifier (such as “so”)
• event class
• cumulative log events missed due to excessive CPU load
• free form text - the event description
Three formats are available for the event timestamp:
4.6.1.16.1 Basic Logging
4
Minor error - graceful recovery
5
Major error - will eventually incapacitate the system
6
Fatal error
Type
Example
0 - seconds.milliseconds
011511.006 -- 1 hour, 15 minutes, 11.006 seconds
since booting.
1 - absolute time with minute resolution
0210281716 -- 2002 October 28, 17:16
2 - absolute time with seconds resolution
1028171642 -- October 28, 17:16:42
Attribute
Permitted
Values
Default
Interpretation
log.level.change.xxx
0-5
4
Control the logging detail level
for individual components.
These are the input filters into
the internal memory-based log
system.
Level
Interpretation
Example:
011511.006|so |2|00|soCoreAudioTermChg: chassis -> idle
time stamp
ID
event class
missed events
text