16 event logging Page 111
Page 111
Administrator Guide - SoundPoint
®
IP / SoundStation
®
IP
Optimization
Copyright © 2004 Polycom, Inc
103
4.6.1.16 Event Logging
The event logging system supports the following classes of events:
ind.gi.x.y.class
positive integer
Assigns the class (defined above) for this indicator.
ind.gi.x.y.physX
IP 300: 0-19
IP 500: 0-159
IP 600: 0-319
IP 4000: 0-247
For GraphicIcon type indicators, this is the x-axis loca-
tion of the upper left corner of the indictor measured in
pixels from left to right.
ind.gi.x.y.physY
IP 300: 0-3
IP 500: 0-79
IP 600: 0-159
IP 4000: 0-67
For GraphicIcon type indicators, this is the y-axis loca-
tion of the upper left corner of the indicator measured in
pixels from top to bottom.
ind.gi.x.y.physW
IP 300: n/a
IP 500: 1-160
IP 600: 1-320
IP 4000: 1-248
For GraphicIcon type indicators, this is the width of the
indicator measured in pixels.
ind.gi.x.y.physH
IP 300: n/a
IP 500: 1-80
IP 600: 1-160
IP 4000: 1-68
For GraphicIcon type indicators, this is the height of the
indicator measured in pixels.
Warning!
Logging parameter changes can impair system operation. Do not change any logging parameters
without prior consultation with Polycom.
Level
Interpretation
0
Debug only
1
High detail event class
2
Moderate detail event class
3
Low detail event class
Attribute
Permitted
Values
Interpretation