beautypg.com

16 event logging

Page 111

background image

Administrator Guide - SoundPoint

®

IP / SoundStation

®

IP

Optimization

Copyright © 2004 Polycom, Inc

103

4.6.1.16 Event Logging

The event logging system supports the following classes of events:

ind.gi.x.y.class

positive integer

Assigns the class (defined above) for this indicator.

ind.gi.x.y.physX

IP 300: 0-19

IP 500: 0-159

IP 600: 0-319

IP 4000: 0-247

For GraphicIcon type indicators, this is the x-axis loca-
tion of the upper left corner of the indictor measured in
pixels from left to right.

ind.gi.x.y.physY

IP 300: 0-3

IP 500: 0-79

IP 600: 0-159

IP 4000: 0-67

For GraphicIcon type indicators, this is the y-axis loca-
tion of the upper left corner of the indicator measured in
pixels from top to bottom.

ind.gi.x.y.physW

IP 300: n/a

IP 500: 1-160

IP 600: 1-320

IP 4000: 1-248

For GraphicIcon type indicators, this is the width of the
indicator measured in pixels.

ind.gi.x.y.physH

IP 300: n/a

IP 500: 1-80

IP 600: 1-160

IP 4000: 1-68

For GraphicIcon type indicators, this is the height of the
indicator measured in pixels.

Warning!

Logging parameter changes can impair system operation. Do not change any logging parameters
without prior consultation with Polycom.

Level

Interpretation

0

Debug only

1

High detail event class

2

Moderate detail event class

3

Low detail event class

Attribute

Permitted
Values

Interpretation