Paradyne T1 T1 Access Mux 926x User Manual
Page 66

Setting Up
5-12
9161-A2-GH30-30
April 1998
Table 5-1.
Network Interface Options (6 of 7)
Alarm Indication Signal (AIS) Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when an alarm indication signal
condition is detected on the network interface.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.
Yellow Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when a yellow alarm condition is
detected on the network interface.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.
Excessive Error Rate (EER) Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
Specifies whether an alarm message is generated when an excessive error rate
condition is detected on the network interface.
H
Excessive Error Rate only appears if Line Framing Format is set to ESF.
Enable – Generates an ASCII alarm message.
Disable – Does not generate an ASCII alarm message.