Dual dsx apm leds – Paradyne T1 T1 Access Mux 926x User Manual
Page 188

OK
SIG
OOF
ALM
SIG
OOF
ALM
9109 DSX
IN
OUT
IN
OUT
IN
OUT
IN
OUT
DSX 2
DSX 1
DSX 2 MON
DSX 1 MON
DSX1
DSX2
97-15642-01
Test
Jacks
LEDs
Troubleshooting
9-6
9161-A2-GH30-30
April 1998
Dual DSX APM LEDs
DSX 1 and DSX 2 Interface LEDs
Label
Indication
Color
What It Means
SIG
Signal
Green
ON
– A recoverable signal is present on the
DSX1/DSX2 interface.
OFF – The signal cannot be recovered from
the DSX1/DSX2 interface. An LOS
condition exists.
OOF
Out of Frame
Yellow
ON
– At least one OOF was detected during
the sampling period.
OFF – No OOFs were detected during the
sampling period.
ALM
Alarm
Yellow
ON
– An alarm condition is present on the
DSX1/DSX2 interface.
Current alarm conditions:
H
Loss of Signal ( LOS )
H
Loss of Frame (LOF)
H
Excessive Error Rate (EER)
H
Yellow
H
Alarm Indication Signal (AIS)
OFF – No alarm condition is present on the
DSX1/DSX2 interface.
General Status LED
Label
Indication
Color
What It Means
OK
Power and
Operational
Status
Green
ON
– The APM has power and is
operational.
OFF – The APM is in a local self-test, or there
is a failure.