beautypg.com

Local analog loopback, Loc analog loop – Paradyne 3810 User Manual

Page 58

background image

Test Branch

8-3

3810-A2-GB30-20

November 1996

Loc Analog Loop

Loc Analog Loop performs a local analog loopback

(CCITT V.54 Loop 3), Figure 8-1, that verifies modem
operation as well as the connection between the DTE and
modem. The modem must be offline to perform this test,
otherwise Invalid Command appears.

To access Loc Analog Loop from the Test branch,

make the following selections:

F1

Test :
Loc_Analog_Loop

F2

F3

Press the

key until Loc Analog Loop appears.

Press any function key to start this test.

F1

Test : Local Loop
Started

F2

F3

The message Started appears on the LCD, and the Test

LED (Model 3810 and Model 3811) lights for the duration
of the test.

If the Test Timeout configuration option is enabled,

Test Timeout appears at the conclusion of the test. If it is
disabled, the test operates until aborted. For more
information on the Test Timeout configuration option,
refer to the Tests section in Chapter 9.

A Ring Indicate during this test can cause errors.

To exit this function and remain in the Test branch,

press the

key. To exit and return to the Top-Level

menu, press the

key.

AT Command Equivalent

The AT command for Local Analog Loopback is &T1.

Figure 8-1. Local Analog Loopback